SS2100EX
• Push button for fire only is Push-to-
Activate, Key-to-Reset
• Unique, curved design helps protect
against accidental activation
• 3 interchangeable / replaceable N.O. or
N.C., SPST gold-plated contact blocks
rated for 3 amp (600 VAC) / 1 amp (250 VDC)
• Lifetime guarantee against breakage in
normal use
• UL / cUL listed, ADA compliant

Protective Coverings
STI-1229HTR
• Stopper® Dome heated environmental
enclosure for signaling appliances
• Maintains operating strobe appliance temperature
with external temperatures to -70oF
• Enables ADA compliant for visual fire protection
systems where freezing temperatures or
other harsh conditions exceed the operating
limits of strobe signal devices
• UL /cUL ambient rating -70oF to 120o

STI-1150
• Alarm cover and gasket to help prevent
false fire alarms to pull stations mounted
indoors or outdoors (flush mounted)
• STI-1155 for surface mounted pull stations
• Red, blue, green or yellow housing available
• Polycarbonate tested to -40oF to 120oF
• UL / cUL, CSFM listed; ADA compliant

SAFETY TECHNOLOGY
INTERNATIONAL
Pull Station Covers
STI-6600
• Helps prevent false fire alarms (smaller version
of Stopper® II), vandalism and accidental
damage to flush mounted units
• Red, blue, green or yellow housing available
• Comes complete with 105 dB horn
• UL / cUL, CSFM listed; ADA compliant

IntelliKnight System Module
5895XL
• Flexput™ I/O circuits (3A each) programmable
as notification, auxiliary or initiation
circuits; 5.0 A output power
• Supports Class A configuration for SBUS
and Flexput circuits; group loop isolation
• 2 Form C programmable relays rated 2.5A
• SBUS repeater conditions RS-485 signal
• 6000 ft wiring distance from 5895XL
• UL 864, CSFM listed; FM / MEA

5104
• Use as Slave / Stand Alone Fire DACT
• Six fully supervised inputs: 1 Class A
(Style D) input, 5 Class B (Style A) inputs
• Downloadable for remote programming
• Dual phone line interface automatic self
tests every 24 hrs (central station report)
• Reports in SIA, major communications
formats; 60 hrs of standby power
• UL 864 listed; FM approved

SK-5235
• 2-Line, 16-character LCD display
• Indicates Trouble, Alarm, Supervisory and
System Status conditions with LEDs /LCD
• Each SK-5235 is supervised by the SK-5208
• Up to 6 per SK-5208 FACP; can be wired up
to 1500 ft. from FACP
• Operation and appearance comparable to
the control panel’s on-board annunciator

SILENT KNIGHT
Fire Control Panels
SK-5208
• 10 zones, 8 Class B (Style B), 2 Class A (Style
D) or Class B (Style B) zones; expandable to 30
• Supervised zone expanders and I/O modules
can be mounted remotely from main panel
• All zones compatible with 2 or 4-wire detectors
• Built-in DACT; 4 NAC; Direct connect port
for on-site up / downloading software